<LOGO>
FM Transmitter Measurement Report
Created: 2024-11-25 19-29-33
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.60 MHz 5/5, 71 dBuV RTL
Pilot RDS Phase Difference
0.0 kHz 3.6 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
3 kHz 66 kHz 17080 0,0234
Modulation Power
Limit Measuring Tolerance
10,0 dBr 3,0 dBr
MIN AVE MAX % above 13,0 dBr
3,3 dBr 4,28 dBr 5,5 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
" RTL " F211 0 (No PTY) 1 0 0 1 21:27, 25.11.2024
RT
"RTL VIVRENSEMBLE "
AF EON
93.2, 93.9, 94.3, 95.3, 95.4, 97.1, 98.9, 99.8, 100.4, 100.5, 101.2, 101.3, 101.5, 102.3, 103.0, 103.6, 103.9, 104.0, 104.1, 104.2, 104.3, 104.4, 105.0, 106.0, 107.5 MHz -
FM Scope Station: 103.60 MHz, signal: 5/5 (71 dBuV) Max at: 66 kHz MIN: 3 kHz % above 75 kHz: 0,0234 Acquired: 2024/11/25 19:28:30 Total samples: 17080 Equivalent time: 0:14:14 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 5,5 dBr MIN: 3,3 dBr AVE: 4,28 dBr % above 13,0 dBr: 0,0 Last value: 4,7 dBr (2024/11/25 19:28:28) Station: 103.60 MHz, signal: 5/5 (71 dBuV) 19:16 19:18 19:20 19:22 19:24 19:26 19:28 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality